By clicking on the button “I accept” or by further usage of this website you express consent with usage of cookies as well as you grant us the permission to collect and process personal data about your activity on this website. More information about personal data processing can be found on this link. Read More

c2_ban1.png

* Data sourced from Ampace Lab. Please refer to actual usage for reference.

Product Parameters


Internal Inverter

2H System

Internal Inverter

4H System

External Inverter

2H System

External Inverter

4H System

Module Configuration530Ah, 1P52S*5530Ah, 1P52S*5530Ah, 1P52S*5530Ah, 1P52S*5
System Configuration (kW /kWh)220 / 440.96125 / 440.96184 / 440.9692 / 440.96
Rated AC Voltage (V)3P4W, 4003P4W, 4003P3W, 4003P3W, 400
Rated Frequency (Hz)50 / 6050 / 6050 / 6050 / 60
Frequency Range (Hz)47.5 - 52.5 / 57.5 - 62.547.5 - 52.5 / 57.5 - 62.545 - 6545 - 65
Max. Charge/Discharge Power (CP)0.5/ 0.50.25 / 0.250.5 / 0.50.25 / 0.25
Max. AC Current(A)349.3174.6292.1146
Backup Function(Black Start)YesYesNoNo
THDV≤3%≤3%≤3%≤3%
Cooling ModePack Liquid Cooling; PCS: Air CoolingPack Liquid Cooling; PCS: Air CoolingPack Liquid Cooling; PCS: Air CoolingPack Liquid Cooling; PCS: Air Cooling
Operation Temperature (℃)-25~55 (>45Derating)-25~55 (>45Derating)-25~55 (>45Derating)-25~55 (>45Derating)
Operating Humidity 5%~95%RH (No Condensation)5%~95%RH (No Condensation)5%~95%RH (No Condensation)5%~95%RH (No Condensation)
IP RatingIP55IP55IP55IP55
Corrosion RatingC4-M (C5-M Optional)C4-M (C5-M Optional)C4-M (C5-M Optional)C4-M (C5-M Optional)
Altitude(m)3000 (>2000 Derating)3000 (>2000 Derating)3000 (>2000 Derating)3000 (>2000 Derating)
Weight(kg)~5000~5000~4950~4950
Dimension (mm)W1470H2490D1500W1470H2490D1500W1470H2490D1500W1470H2490D1500
Noise(dB)65656565
PCS Installation MethodFactory Assembly, IntegratedFactory Assembly, IntegratedOn Site Assembly, External MountedOn Site Assembly, External Mounted
Communication InterfaceEthernet, RS485Ethernet, RS485Ethernet, RS485Ethernet, RS485
CertificationIEC62619, IEC62477, IEC62109, IEC62933, ISO13849 PLC, UL9540A, IEC61000-2-4, UN38.3, EU Battery LawIEC62619, IEC62477, IEC62109, IEC62933, ISO13849 PLC, UL9540A, IEC61000-2-4, UN38.3, EU Battery LawIEC62619, IEC62477, IEC62109, IEC62933, ISO13849 PLC, UL9540A, IEC61000-2-4, UN38.3, EU Battery LawIEC62619, IEC62477, IEC62109, IEC62933, ISO13849 PLC, UL9540A, IEC61000-2-4, UN38.3, EU Battery Law
Grid CodesGermany(VDE4105/4110/4120), Italy, Spain, Poland, UK, Greece, Norway, Sweden, Finland, Netherlands, Bulgaria, Belgium, Israel, AustraliaGermany(VDE4105/4110/4120), Italy, Spain, Poland, UK, Greece, Norway, Sweden, Finland, Netherlands, Bulgaria, Belgium, Israel, AustraliaGermany(VDE4105/4110/4120), Italy, Spain, Poland, UK, Greece, Norway, Sweden, Finland, Netherlands, Bulgaria, Belgium, Israel, AustraliaGermany(VDE4105/4110/4120), Italy, Spain, Poland, UK, Greece, Norway, Sweden, Finland, Netherlands, Bulgaria, Belgium, Israel, Australia
FFSSmoke sensor, Heat sensor, Gas sensor, Audible & Visual alarm, Aerosol, Water port, Ventilation system, Explosion venting panelSmoke sensor, Heat sensor, Gas sensor, Audible & Visual alarm, Aerosol, Water port, Ventilation system, Explosion venting panelSmoke sensor, Heat sensor, Gas sensor, Audible & Visual alarm, Aerosol, Water port, Ventilation system, Explosion venting panelSmoke sensor, Heat sensor, Gas sensor, Audible & Visual alarm, Aerosol, Water port, Ventilation system, Explosion venting panel
封面图.jpg

Get Your Customized Solution Now

Address your power challenges and get a tailored solution. Click to claim our service